钢筋混凝土筒仓设计标准 [附条文说明] GB50077-2017 建标库

附录G  星仓仓壁及洞口应力计算

G.0.1  二列式圆形群仓星仓(图G.0.1)仓壁的内力应按下列公式计算:

MA=p(dn+2t)(dn+t)sinθ(1-sinθ/θ)/4       (G.0.1-1)

MB=p(dn+2t)(dn+t)sinθ(cosθ-sinθ/θ)/4       (G.0.1-2)

MC=p(dn+2t)(dn+t)sinθ(cosα1-sinθ/θ)/4       (G.0.1-3)

FA=p(dn+2t)(1-sinθ)/2       (G.0.1-4)

FB=p(dn+2t)(1-sinθcosθ)/2       (G.0.1-5)

FC=p(dn+2t)(1-sinθcosα1)/2       (G.0.1-6)

    式中:MA、MB、MC——图G.0.1中各点的弯矩;

        FA、FB、FC——图G.0.1中各点的环向轴力;

        p——贮料侧压力。

G.0.2  三列式圆形群仓星仓(图G.0.2)仓壁的内力应按下列公式计算:

MA=—0.0352p(dn+t)       (G.0.2-1)

MB=(0.3183-0.3535cosθ)p(dn+t)       (G.0.2-2)

MC=(0.3183-0.3535cosα1)p(dn+t)       (G.0.2-3)

MD=0.0683p(dn+t)       (G.0.2-4)

FA=—0.7071p       (G.0.2-5)

FB=—0.7071pcosθ       (G.0.2-6)

FC=—0.7071pcosα1       (G.0.2-7)

FD=—0.5p       (G.0.2-8)

VA=0       (G.0.2-9)

VB=0.7071psinθ       (G.0.2-10)

VC=0.7071psinα1       (G.0.2-11)

VD=0.5p       (G.0.2-12)

    式中:MA、MB、MC、MD——图G.0.2中各点的弯矩;

        FA、FB、FC、FD——图G.0.2中各点的环向轴力;

        VA、VB、VC、VD——图G.0.2中各点的切力。

G.0.3  仓壁上正方形、矩形洞口的周边(图G.0.3),在拉、压力p作用下的洞口应力应按表G.0.3-1~表G.0.3-3中的参数计算。